IM300 Series power meter

The IM300 series of power intelligent monitoring instruments are intelligent devices for medium and low voltage systems (6 to 35kV and 0.4kV). They have powerful data acquisition, processing, statistics and control functions, enabling measurement and calculation of basic single-loop AC parameters. Power accumulation, fault record, 2 to 31 harmonic monitoring functions, 4-way switch input monitoring, 2-way relay output, 1 channel 4~20mA DC transmission output, over-limit alarm and other functions. The IM300 provides a communication interface that supports the RS485 interface MODBUS communication protocol and is connected to a computer monitoring system.

Product Details

IM300 basic functions

--

Supports three-phase three-wire system and three-phase four-wire system optional functions, with three-phase voltage, three-phase current, zero-sequence current, total active power, and total reactive power

Rate, total apparent power, active power of each phase, reactive power, apparent power, total power factor, power factor of each phase, system frequency, total active power, total reactive power, active energy of each phase And measurement and calculation functions of reactive power.

-- Harmonic distortion rate of voltage and current (including total distortion rate THD, odd distortion rate, even distortion rate), voltage 2 to 31 harmonic component occupancy, current 2 to 31 harmonic component occupancy, Measurement and calculation functions of the fundamental rms value of the voltage, the fundamental rms value of the current, and the like.

-- as 2 relay control outputs.

-- It has a maximum of 4 switching inputs; it can record up to 32 switching SOE events.

-- It has a 4-way 4~20mA DC transmission output function, which can be arbitrarily associated with voltage, current and power.

-- Positive and negative total active energy, four-quadrant reactive energy accumulation. Positive and negative total active maximum demand and occurrence time, positive and negative total reactive maximum demand and occurrence time.

-- Phase/line voltage, current, frequency, total/three-phase power factor, total/three-phase active power, reactive power, maximum/minimum apparent power and time of occurrence。

-- Three-phase voltage and current imbalance.

--The electrical parameters are associated with the relay and perform over-limit alarm control to support overcurrent, zero current, ground, low voltage, over voltage, low frequency, over frequency, low power factor over limit alarms.

-- You can view the various electrical parameters and operating status of a circuit and switch locally; you can view or set the operating parameters, and perform operations such as closing and opening.

--The communication protocol is about MODBUS-RTU, with remote monitoring, maintenance and management functions.

-- The clock is free to set the time and date of the century.

*Note: The above functions are selected according to the specific models of the device.